Bill Brodhead WPB Enterprises Inc
Radon & Vapor Intrusion |
Bill Brodhead WPB Enterprises Inc.
Radon & Vapor Intrusion |
|
WPB Commercial Jobs800-360-8004WPB has installed radon remediation & vapor intrusion mitigation systems for schools and commercial buildings, as well as for US Navy, Air Force and Army housing in the Pacific & United States |
Download WPB Resume References Lots of Info page Commercial job photos Military job photos WPB Home Example of WPB VIM - VOC Mitigation Design Bill Brodhead's current NRPP Radon Mitigation mitigation certification. |
Watch Webinar where Bill explains issues with
Commercial
& School mitigation
|
WPB Commercial Jobs800-360-8004WPB has installed radon remediation & vapor intrusion mitigation systems for schools and commercial buildings, as well as for US Navy, Air Force and Army housing in the Pacific & United States |
Download WPB Resume Example of WPB VIM - VOC Mitigation Design Bill Brodhead's current NRPP mitigation certification. |
1991 to present |
Instructor for Rutgers Eastern Regional Radon Training Center three day radon mitigation course. This course fulfills training requirement for NEHA and NRSB radon mitigation certification. |
||
2008 to present |
Accepted position to chair the ASTM task group (E06.41-3). This ASTM task group addresses radon mitigation documents known as E2121 (existing homes) and E1465 (new construction). |
||
2011 |
Designed radon mitigation system based on pressure field extension measurements for 24,000 ft2 office building for Lehigh University, Bethlehem, PA. |
||
2011 |
Designed vapor intrusion mitigation system based on pressure field extension measurements for 250,000 ft2 factory in St. Johns Michigan. |
||
2011 |
Designed vapor intrusion mitigation (VIM) systems for five Marine Corp buildings at Camp Lejuene, NC for CH2MHill |
||
2010 |
Designed and Installed vapor intrusion mitigation (VIM) system for 18,000 ft2 shopping mall in Newark NJ (Whitman Engineers) |
||
2010 |
Hired to design Vapor intrusion mitigation system for 12,000 ft2 shopping mall in West Orange, NJ |
||
2009 |
Installed 15 commercial radon mitigation systems for Fort Campbell Army base in Clarksville Tenn. |
||
2009 |
Hired to design a vapor intrusion mitigation system for 250,000 ft2 American Dryer manufacturing plant in Rhode Island. |
||
2009 |
Designed and installed a vapor intrusion mitigation (VIM) system for a 4,500 ft2 apartment building in Washington NJ (WRS Engineering). |
||
2008 |
Taught 8 hour continuing education class for Ohio Radon Professional Organization on designing and installing soil gas mitigation systems in commercial buildings |
||
2008 |
Hired by Dalhousie University in Halifax, Nova Scotia to teach 3 day class to implement a radon mitigation plan for Nova Scotia School Districts |
||
2007-8 |
Provided diagnostic report to make concrete flux measurements and determine ventilation requirements for 8 story & 5 story condominium in Charlotte NC |
||
2007-8 |
Hired by Goss International to design soil vapor intrusion system for 235,000 square foot factory in Dover, NH |
||
2007 |
Designed & Taught 8 hour Commercial Radon & Soil Vapor Intrusion Mitigation CE Course at International Radon Conference |
||
2006 |
Hired by Earth Tech a division of Tyco to install soil vapor intrusion systems in 11 homes contaminated with TCE/PCE in Akron, PA |
||
2006 |
Installed 150 mitigation systems for US Army housing at Fort Campbell, Clarksville, Tennessee |
||
2006 |
Hired by CH2M-Hill to supervise an additional installation of 22 radon mitigation systems at Kadena Air Force Base, Okinawa, Japan |
||
2005 |
Designed and installed a radon mitigation system for a half million square foot warehouse outside of Allentown, PA |
||
2005 |
Hired by Oak Ridge National Laboratory to mitigate over 130 military homes for the US Navy on the island of Guam. Work was accomplished in four weeks with four, two man crews. All re-tests were below the EPA radon guideline level. |
||
2005 |
Hired by CH2M Hill to supervise mitigation of Air Force housing at Kadena Air Force Base in Okinawa, Japan. |
||
2004 |
Hired to evaluate radon levels and make remedial recommendations for the Allentown branch of St. Lukes hospital. |
||
2003 |
Hired by an engineering firm (CH2M-Hill) to evaluate the existing 500+ radon mitigation systems at Kadena Air Force Base, Okinawa, Japan and to provide guidance on radon testing procedures. |
||
2002 |
Hired by a government contracting firm (BWXT Y12) to do radon diagnostics and assist in the design of radon mitigation systems for the US Navy in Okinawa, Japan. Eighty-five radon systems were installed during a second four week trip with five, two man crews. All re-tests were below the EPA radon guideline level. |
||
2001 |
Hired by a government contracting firm (BWXT Y12) to mitigate over 250 homes for the US Navy on the island of Guam. Work was accomplished in two, four week periods with five, two man crews during the first trip and two crews during the second trip. |
||
2000-03 |
Hired by United States Office of Surface Mining to mitigate six homes that had excessive amounts of CO2 entering the basement. |
||
2000 |
Hired by Lockheed Martin Energy Systems to mitigate 50 homes for the US Navy on the Island of Guam. Work was accomplished in one four week period with two crews of two each. |
||
1999 |
Installed radon system for Cold Spring Elementary School, Central Bucks School District. |
||
1999 |
Hired by Montgomery County to install a mitigation system at the underground Montgomery County Emergency Operations Center ( 911 Center ). |
||
1998 |
Installed a radon system for the Lehigh Elementary School in Northampton Area School District. |
||
1997-98 |
Hired by Oak Ridge National Lab to mitigate 100 housing units for the US Navy on the island of Guam. Radon levels were in some cases over 100 pCi/L. Three trips were made to Guam with three to four individuals during each trip. |
||
1995-96 |
Hired by EPA for a Large Building Research Project to provide building measurements, radon mitigation diagnostics and a mitigation plan for the 45,000 square foot, four story, State Office Building in Reading. |
||
1995 |
Hired by the US Army to provided diagnostics and radon system recommendations for Fitness Research Institute Building at Carlisle Pennsylvania Army Facility. |
||
1995 |
Hired by Bryn Mawr College outside Philadelphia to mitigate a 4 story teaching facility. |
||
1994 |
Hired by environmental company to provide diagnostics and specifications for remediation of a 4 story office building in Chicago, IL. |
||
1989-90 |
Designed and implemented the mitigation system for a school in NJ that had radon levels as high as 200 pCi/L. |
||
1989 |
Designed a successful mitigation system for a newspaper facility in PA and six NJ State Police Headquarters. |
||
1989 |
Mitigated two schools in PA. |
If you have any questions please feel free to call Bill at (610) 346-8004 |
1991 to present |
Instructor for Rutgers Eastern Regional Radon Training Center three day radon mitigation course. This course fulfills training requirement for NEHA and NRSB radon mitigation certification. |
||
2008 to present |
Accepted position to chair the ASTM task group (E06.41-3). This ASTM task group addresses radon mitigation documents known as E2121 (existing homes) and E1465 (new construction). |
||
2011 |
Designed radon mitigation system based on pressure field extension measurements for 24,000 ft2 office building for Lehigh University, Bethlehem, PA. |
||
2011 |
Designed vapor intrusion mitigation system based on pressure field extension measurements for 250,000 ft2 factory in St. Johns Michigan. |
||
2011 |
Designed vapor intrusion mitigation (VIM) systems for five Marine Corp buildings at Camp Lejuene, NC for CH2MHill |
||
2010 |
Designed and Installed vapor intrusion mitigation (VIM) system for 18,000 ft2 shopping mall in Newark NJ (Whitman Engineers) |
||
2010 |
Hired to design Vapor intrusion mitigation system for 12,000 ft2 shopping mall in West Orange, NJ |
||
2009 |
Installed 15 commercial radon mitigation systems for Fort Campbell Army base in Clarksville Tenn. |
||
2009 |
Hired to design a vapor intrusion mitigation system for 250,000 ft2 American Dryer manufacturing plant in Rhode Island. |
||
2009 |
Designed and installed a vapor intrusion mitigation (VIM) system for a 4,500 ft2 apartment building in Washington NJ (WRS Engineering). |
||
2008 |
Taught 8 hour continuing education class for Ohio Radon Professional Organization on designing and installing soil gas mitigation systems in commercial buildings |
||
2008 |
Hired by Dalhousie University in Halifax, Nova Scotia to teach 3 day class to implement a radon mitigation plan for Nova Scotia School Districts |
||
2007-8 |
Provided diagnostic report to make concrete flux measurements and determine ventilation requirements for 8 story & 5 story condominium in Charlotte NC |
||
2007-8 |
Hired by Goss International to design soil vapor intrusion system for 235,000 square foot factory in Dover, NH |
||
2007 |
Designed & Taught 8 hour Commercial Radon & Soil Vapor Intrusion Mitigation CE Course at International Radon Conference |
||
2006 |
Hired by Earth Tech a division of Tyco to install soil vapor intrusion systems in 11 homes contaminated with TCE/PCE in Akron, PA |
||
2006 |
Installed 150 mitigation systems for US Army housing at Fort Campbell, Clarksville, Tennessee |
||
2006 |
Hired by CH2M-Hill to supervise an additional installation of 22 radon mitigation systems at Kadena Air Force Base, Okinawa, Japan |
||
2005 |
Designed and installed a radon mitigation system for a half million square foot warehouse outside of Allentown, PA |
||
2005 |
Hired by Oak Ridge National Laboratory to mitigate over 130 military homes for the US Navy on the island of Guam. Work was accomplished in four weeks with four, two man crews. All re-tests were below the EPA radon guideline level. |
||
2005 |
Hired by CH2M Hill to supervise mitigation of Air Force housing at Kadena Air Force Base in Okinawa, Japan. |
||
2004 |
Hired to evaluate radon levels and make remedial recommendations for the Allentown branch of St. Lukes hospital. |
||
2003 |
Hired by an engineering firm (CH2M-Hill) to evaluate the existing 500+ radon mitigation systems at Kadena Air Force Base, Okinawa, Japan and to provide guidance on radon testing procedures. |
||
2002 |
Hired by a government contracting firm (BWXT Y12) to do radon diagnostics and assist in the design of radon mitigation systems for the US Navy in Okinawa, Japan. Eighty-five radon systems were installed during a second four week trip with five, two man crews. All re-tests were below the EPA radon guideline level. |
||
2001 |
Hired by a government contracting firm (BWXT Y12) to mitigate over 250 homes for the US Navy on the island of Guam. Work was accomplished in two, four week periods with five, two man crews during the first trip and two crews during the second trip. |
||
2000-03 |
Hired by United States Office of Surface Mining to mitigate six homes that had excessive amounts of CO2 entering the basement. |
||
2000 |
Hired by Lockheed Martin Energy Systems to mitigate 50 homes for the US Navy on the Island of Guam. Work was accomplished in one four week period with two crews of two each. |
||
1999 |
Installed radon system for Cold Spring Elementary School, Central Bucks School District. |
||
1999 |
Hired by Montgomery County to install a mitigation system at the underground Montgomery County Emergency Operations Center ( 911 Center ). |
||
1998 |
Installed a radon system for the Lehigh Elementary School in Northampton Area School District. |
||
1997-98 |
Hired by Oak Ridge National Lab to mitigate 100 housing units for the US Navy on the island of Guam. Radon levels were in some cases over 100 pCi/L. Three trips were made to Guam with three to four individuals during each trip. |
||
1995-96 |
Hired by EPA for a Large Building Research Project to provide building measurements, radon mitigation diagnostics and a mitigation plan for the 45,000 square foot, four story, State Office Building in Reading. |
||
1995 |
Hired by the US Army to provided diagnostics and radon system recommendations for Fitness Research Institute Building at Carlisle Pennsylvania Army Facility. |
||
1995 |
Hired by Bryn Mawr College outside Philadelphia to mitigate a 4 story teaching facility. |
||
1994 |
Hired by environmental company to provide diagnostics and specifications for remediation of a 4 story office building in Chicago, IL. |
||
1989-90 |
Designed and implemented the mitigation system for a school in NJ that had radon levels as high as 200 pCi/L. |
||
1989 |
Designed a successful mitigation system for a newspaper facility in PA and six NJ State Police Headquarters. |
||
1989 |
Mitigated two schools in PA. |